Signal converter (DIN Rail Type) |
 |
|
|
|
|
DP-Series(One Output) |
|
- Improvement of Realiability by Hybrid Package - Actualization of High Accuracy - Compact Shape and Easy Handling - Dimension(W50 * H80 * D128mm) - CE Certificate |
|
|
|
|
|
|
|
|
|
|
|
|
|
DW-Series(Two Outputs) |
|
- Two Isolated Outputs Converter - Improvement on Reliability by Hybrid Package - Actualization of High Accuracy - Compact Shape and Easy Handling - Dimension (W50 * H80 * D137mm |
|
|
|
|
|
|
|
|
|
|
 |
Signal converter (Rack / Wall Mount Type) |
 |
|
|
|
|
DS-Series(One Output) |
|
- Improvement on Reliability by Hybrid Package - Actualization of High Accuracy - Compact Shape and Easy Handling - Capability of RACK & WALL MOUNTING - Dimension(W42 * H90 * D120mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
DT-Series(Two Outputs) |
|
- Two Isolated Outputs Converter - Improvement on Reliability by Hybrid Package - Actualization of High Accuracy - Capability of RACK & WALL MOUNTING - Dimension(W42 * H90 * D120mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
DM-Series(Four Outputs) |
|
- Four Isolated Outputs Converter - Improvemnet on Reliability by Hybrid Package - Actualization of High Accuracy - Capability of RACK & WALL MOUNTING - Dimension(W90 * H90 * D170mm) |
|
|
|
|
|
|
|
|
|
|
 |
Signal converter (Rack / DIN Rail Type) |
 |
|
|
|
|
DV-Series(One&Two Outputs) |
|
- One&Two Isolated Outputs Converter - Improvement on Reliability by Hybrid Package - Actualization of High Accuracy - Free Voltage Power(AC 85~264V) - Capability of RACK & WALL MOUNTING - Dimension(W42 * H96 * D101 mm) - CE Certificate |
|
|
|
|
|
|
|
|
|
|
 |
Alarm module (DIN Rail Type) |
 |
|
|
|
|
DA-Series(Two Outputs) |
|
- Plug-in Type Alalrm Setter - HH/H, H/L, L/LL, Alarm Function - Actualization of High Accuracy - Compact Shape and Easy Handling - Free Voltage Power(AC 85~264V) - Dimension(W50 * H80 * D137 mm) |
|
|
|
|
|
|
|
|
|
|
 |
Digital Universal signal converter (DIN Rail Type) |
 |
|
|
|
|
DZWT-Series(Two Outputs) |
|
- Multy Input Range(T/C, RTD, DC mV, V, mA, X'TR) - Input Scale Function(-9.999 ~ +9.999, -9999 ~ +9999) - Alarm Type Selection Function(HH/H, H/L, L/LL) - 7-Segment LED Display - Free Voltage power(AC 85~264V) - Dimension(W50 * H96 * D112 mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
DFC-Series(Two Outputs) |
|
- Scale Ability Input of Three Wire RTD, T/C Voltage and DC Current - Universal DC Voltage/Current Output - PC Configure ability - Input Scaling Function - Output Scaling Function - Bar-Graph Display or 7 Segment LED Display - Digital Communications(RS-485) - CE Certificate |
|
|
|
|
|
|
|
|
|
|
|
|
|
SA100-Series(One Out) |
|
- Simple Mounting on DIN Rail - Corresponding to Various Applications - Analog Retransmission Output - Digital Communications - Advanced Self-Configulation |
|
|
|
|
|
|
|
|
|
|
 |
Signal converter (19Inch Rack Type) |
 |
|
|
|
|
DZRT-Series(12 Channel) |
|
- Multi Inputs(T/C, RTD, DC Voltage DC Current, X'TR) - ¡¾ 0.1%High Accuracy - Input Scaling Function(-9.999 ~ +9.999, -9999 ~ +9999) - Output Scaling Function - Alarm Type Selection Function(HH/H, H/L, L/LL) - Reverse Output Function - Output Isolation by Photo-Coupler - One Input ~ Three Outputs |
|
|
|
|
|
|
|
|
|
|
|
|
|
DU-Series(10 Channel) |
|
- One&Two Isolated Outputs Converter - Improvement on Reliability by Hybrid Package - Actualization of High Accuracy - Solution of Inconvenience of Maintenance - Following Collective Power Supply - Capability of RACK & WALL MOUNTING - Dimension Rack Type(W483 * H132 * D183mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
ZEST-Series(16 Channel) |
|
- Common Power Supply to Each I/O Module via the Installation BASE Terminals - Two Isolated Outputs Converter - Actualization of High Accuracy - Max 16 Channel Input Modules Mounted on the BASE - Digital Communication - CE Certificate |
|
|
|
|
|
|
|
|
|
|
 |
Signal converter (Small DIN Rail Type) |
 |
|
|
|
|
DE-Series(Two Outputs) |
|
1. DE : None Display 2. 1 &2 Isolated Outputs 3. Input : Multi Range Inputs (RTD, T/C , DC Voltage/Current) 4. Output : DC Voltage signal or DC Current 5. High Accuracy : DC(¡¾0.1% Max), RTD/PULSE(¡¾0.2% Max),T/C(¡¾0.25% Max), PT/CT(¡¾0.3% Max) 6. Response Time : Less than 0.15 Sec(0~90%) 7. Power supply : Free Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
|
DK-Series(Two Outputs) |
|
1. DK : Display 2. One&Two Isolated Outputs 3. Input : Multi Range (RTD, T/C , DC Voltage/Current) 4. Output : DC Voltage / Current , Relay Contact, RS-485 5. High Accuracy : ¡¾0.1% 6. Response Time : 0.2sec (0~90% of span) 7. Communication : RS-485 (Two Wires), Modbus 8. Power supply : Free Voltage AC 85~264V, DC 24V
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DL-Series(Two Outputs) |
|
1. 4~20mA DC Two Wires Outputs 2. Input : Multi Range (RTD, P/C , DC Voltage/Current) 3. Output : DC Voltage / Current , Relay Contact 4. High Accuracy : ¡¾0.1% 5. Response Time : 0.2sec (0~90% of span) 6. Power supply : DC12~28V
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DL2 series |
|
Slim type Signal Converter Input : Multi Range (Potentiometer, TC, RTD, 4-20mA DC) Output : Multi Output sellecting one (Order Code) Isolation : Input - Output - Power Power : DC 24V |
|
|
|
|
|
|
|
|
|
|
|
|
|
DQ series |
|
- Actualization of high accuracy - DC 24V Power supply - Small & slim size - Dimension (W33¡¿H108¡¿D59)
|
|
|
|
|
|
|
|
|
|
|
 |
Signal converter (Small terminal DIN Rail Type) |
 |
|
|
|
|
DMS3000-Series |
|
- Ultra-compact JIS-Concord Size - Humid-Resistant Coating as Standard Specification - International Safety Standard Compatible |
|
|
|
|
|
|
|
|
|
|
|
|
|
DMS3700-Series |
|
- Isolated Dual Output in a Miniaturized Package - Humid-Resistant Coating as Standard Specification - Gold-Plating on Contact Parts for High Reliability and Durability |
|
|
|
|
|
|
|
|
|
|
 |
AC POWER TRANSDUCER |
 |
|
|